An error has occurred. Please reload the page.
Please see the technical note under "Downloads"
List price: | Please log in |
---|
Application | |||||||||
---|---|---|---|---|---|---|---|---|---|
Media | hydrous coolants; oils; oil-based media; water; media similar to water | ||||||||
Dielectric constant of the medium | > 2 | ||||||||
Cannot be used for | extremely conductive media; adhering media; granulates; bulk material; acids; alkali | ||||||||
Tank pressure [bar] | 0.5; (when mounting with mounting accessories: E43001 - E43007, E43019) | ||||||||
coolants | |||||||||
Medium temperature [°C] | 0...35; (with climatic tube E43102) | ||||||||
oil | |||||||||
Medium temperature [°C] | 0...70 | ||||||||
Medium temperature short time [°C] | 0...90; (< 1 h) | ||||||||
water | |||||||||
Medium temperature [°C] | 0...35; (with climatic tube E43102 35...55 °C) | ||||||||
Electrical data | |||||||||
Operating voltage [V] | 18...30 DC | ||||||||
Current consumption [mA] | < 50 | ||||||||
Protection class | III | ||||||||
Reverse polarity protection | yes | ||||||||
Power-on delay time [s] | < 3 | ||||||||
Inputs / outputs | |||||||||
Number of inputs and outputs | Number of digital outputs: 2 | ||||||||
Outputs | |||||||||
Total number of outputs | 2 | ||||||||
Output signal | switching signal; IO-Link | ||||||||
Electrical design | PNP/NPN | ||||||||
Number of digital outputs | 2 | ||||||||
Output function | normally open / normally closed; (parameterisable) | ||||||||
Max. voltage drop switching output DC [V] | 2.5 | ||||||||
Permanent current rating of switching output DC [mA] | 200 | ||||||||
Short-circuit protection | yes | ||||||||
Type of short-circuit protection | thermal, pulsed | ||||||||
Overload protection | yes | ||||||||
Measuring/setting range | |||||||||
Factory setting | hydrous coolants; water; media similar to water | ||||||||
Probe length L [mm] | 728 | ||||||||
Active range A [mm] | 585 | ||||||||
Inactive range I1 / I2 [mm] | 104 / 39 | ||||||||
Setting range | |||||||||
Set point SP [mm] | 60...590 | ||||||||
Reset point rP [mm] | 50...580 | ||||||||
In steps of [mm] | 10 | ||||||||
Reference point OP [mm] | 200 - 240 - 280 - 310 - 350 - 390 - 420 - 460 - 500 - 530 - 570 - 610- OFF | ||||||||
Hysteresis, OP [mm] | 4 | ||||||||
Accuracy / deviations | |||||||||
Measuring error [% of the final value] | ± 5 | ||||||||
Repeatability | ± 2 | ||||||||
Resolution [mm] | 5 | ||||||||
Software / programming | |||||||||
Parameter setting options | hysteresis / window; normally open / normally closed; switching logic; SP/rP position; adjustment OP; medium selection; offset setting; switch-on/switch-off delay | ||||||||
Interfaces | |||||||||
Communication interface | IO-Link | ||||||||
Transmission type | COM2 (38,4 kBaud) | ||||||||
IO-Link revision | 1.1 | ||||||||
SDCI standard | IEC 61131-9 | ||||||||
IO-Link device ID | 0x00028E | ||||||||
Profiles | Smart Sensor: Process Data Variable; Device Identification, Device Diagnosis | ||||||||
SIO mode | yes | ||||||||
Required master port type | A | ||||||||
Process data analogue | 2 | ||||||||
Process data binary | 2 | ||||||||
Min. process cycle time [ms] | 3.2 | ||||||||
Operating conditions | |||||||||
Ambient temperature [°C] | 0...60 | ||||||||
Storage temperature [°C] | -25...80 | ||||||||
Protection | IP 67 | ||||||||
Tests / approvals | |||||||||
EMC |
|
||||||||
Shock resistance |
|
||||||||
Vibration resistance |
|
||||||||
MTTF [years] | 265 | ||||||||
Mechanical data | |||||||||
Weight [g] | 506.6 | ||||||||
Dimensions [mm] | Ø 16 | ||||||||
Materials | stainless steel (1.4301 / 304); stainless steel (1.4404 / 316L); FKM; NBR; PBT; PC; PA; PP; TPV | ||||||||
Materials (wetted parts) | PP | ||||||||
Displays / operating elements | |||||||||
Display |
|
||||||||
Remarks | |||||||||
Notes | Please see the technical note under "Downloads" | ||||||||
Pack quantity | 1 pcs. | ||||||||
Electrical connection | |||||||||
Connection | Connector: 1 x M12; Contacts: gold-plated | ||||||||
ifm electronic gmbh • Friedrichstraße 1 • 45128 Essen — We reserve the right to make technical alterations without prior notice. — EN-GB — LK1024-03 — 13.05.2016 — |
Document | Size | Type |
---|---|---|
IO-LINK-Approval | 921.0 kB | |
EAC-Approval | 984.0 kB | |
cRUus,cULus,UL-Approval | 449.0 kB | |
EU declaration of conformity | 606.0 kB | |
Certificates / Protocols | HTML | |
MTTFd certificate | 28.0 kB | |
REACH RoHS declaration | 26.0 kB | |
China RoHS declaration | 140.0 kB |
Documents | Size | Type |
---|---|---|
Operating instructions (English, ) | 545.0 kB | |
Operating instructions (Czech, ) | 604.0 kB | |
Operating instructions (German, ) | 512.0 kB | |
Operating instructions (Spanish, ) | 583.0 kB | |
Operating instructions (French, ) | 599.0 kB | |
Operating instructions (Japanese, ) | 786.0 kB | |
Operating instructions (Korean, ) | 639.0 kB | |
Operating instructions (Polish, ) | 606.0 kB | |
Operating instructions (Russian, ) | 617.0 kB | |
Technical note | 145.0 kB | |
List of ifm contacts | 143.0 kB |
CAD file format | File name | Size | Type |
---|---|---|---|
DWG (2D) | CAD_DWG_160_0049_LK1024.ZIP | 51.1 kB | ZIP |
DXF (2D) | CAD_DXF_160_0027_LK1024.ZIP | 654.8 kB | ZIP |
SAT (3D) | CAD_SAT_160_0049_LK1024.ZIP | 103.4 kB | ZIP |
STP (3D) | CAD_STP_160_0049_LK1024.ZIP | 62.2 kB | ZIP |
Further CAD file formats (external provider)
Note: Please note that the CAD data are slightly simplified and only show a medium level of detail. Manufacturing tolerances have to be taken into account.
eCl@ss 5.1.3 | 27-37-18-13 |
---|---|
eCl@ss 6.1 | 27-37-18-13 |
eCl@ss 7.1 | 27-37-18-13 |
eCl@ss 8.1 | 27-37-18-13 |
ETIM 4.0 | EC-00-14-47 |
UNSPSC 5.0301 | 41-11-37-10 |
UNSPSC 6.0315u | 41-11-37-10 |
Tender text Download RTF version | |
---|---|
Electronic level sensor; Operating voltage 18...30 DC V; Level measurement 0.05...0.636 m; PNP/NPN; M12 Connector; Gold-plated contacts | |
Product designation | Electronic level sensor |
Application | hydrous coolants,oils,oil-based media,water,media similar to water |
Operating voltage DC | 18...30 V |
Voltage type | DC |
Electrical design | PNP/NPN |
Total number of outputs | 2 |
Output function | normally open / normally closed; (parameterisable) |
Output signal | switching signal; IO-Link |
Level measurement | 0.05...0.636 m |
Active range A | 585 mm |
Inactive range I1 / I2 | 104 / 39 mm |
Probe length L | 728 mm |
Parameter setting options | hysteresis / window; normally open / normally closed; switching logic; SP/rP position; adjustment OP; medium selection; offset setting; switch-on/switch-off delay |
Connection | M12 Connector |
Materials | stainless steel (1.4301 / 304); stainless steel (1.4404 / 316L); FKM; NBR; PBT; PC; PA; PP; TPV |
Materials (wetted parts) | PP |
Display | display unit / status: 2 x LED green (cm, inch); switching status: 2 x LED yellow; measured values: alphanumeric display 4-digit; parameter setting: alphanumeric display 4-digit |
Protection | IP 67 |
Protection class | III |
Ambient temperature | 0...60 °C |
Medium temperature | 0...70 °C |
Communication interface | IO-Link |
Brand | ifm electronic gmbh or equivalent |
Type | LK1024 |