FMB50-2LA7/0 (FMB50-AA22IA1FGAUPJB3U)(Deltapilot M)
Approval: Non-hazardous area
Output:4-20mA HART
Display, Operation: W/o LCD, push button on electronics
Housing: F31 Alu
Electrical Connection:Gland M20, IP66/68 NEMA4X/6P
Sensor Range:400mbar/40kPa/6psi gauge, 4mH2O/13ftH2O/160inH2O overload: 8bar/800kPa/120psi
Reference Accuracy: Standard
Calibration; Unit:Sensor range; %
Process Connection: Universal adapter 44mm 316L, silicone shape seal 3A, EHEDG
Membrane Material:AlloyC
Fill Fluid: Synthetic oil, FDA
Seal: None, cell welded