PMP51-7HF9/0(PMP51-AA21JA1WGBGCJA1+AA)(Cerabar M)
Approval:Non-hazardous area
Output:4-20mA HART
Display, Operation: LCD, push button on display/electronics
Housing: F31 Alu, glass window
Electrical Connection: Gland M20, IP66/68 NEMA4X/6P
Sensor Range: 400bar/40MPa/6000psi gauge, 4000mH2O/13340ftH2O/160000inH2O overload: 600bar/60MPa/9000psi
Reference Accuracy:Standard
Calibration; Unit: Sensor range; mbar/bar
Process Connection: Thread ISO228 G1/2 EN837, 316L
Membrane Material: 316L
Fill Fluid: Silicone oil